201 research outputs found

    Electronically Tunable Resistorless Mixed Mode Biquad Filters

    Get PDF
    This paper presents a new realization of elec¬tronically tunable mixed mode (including transadmittance- and voltage-modes) biquad filter with single input, three outputs or three inputs, single output using voltage differ-encing transconductance amplifier (VDTA), a recently introduced active element. It can simultaneously realize standard filtering signals: low-pass, band-pass and high-pass or by selecting input terminals, it can realize all five different filtering signals: low-pass, band-pass, high-pass, band-stop and all-pass. The proposed filter circuit offers the following attractive feature: no requirement of invert-ing type input signal which is require no addition circuit, critical component matching conditions are not required in the design, the circuit parameters ω0 and Q can be set orthogonally or independently through adjusting the bias currents of the VDTAs, the proposed circuit employs two active and minimum numbers of passive components. Fur-thermore, this filter was investigated from the point of view of limited frequency range, stability conditions, effects of parasitic elements and effects of non-ideal and sensitivity. Thus, taking these effects and conditions into considera¬tion, working conditions and boundaries of this filter are determined. We also performed Monte Carlo, THD and noise analyses. Simulation results are given to confirm theoretical analyses

    New Simple CMOS Realization of Voltage Differencing Transconductance Amplifier and Its RF Filter Application

    Get PDF
    The voltage differencing transconductance amplifier (VDTA) is a recently introduced active element for analog signal processing. However, the realization of VDTA is not given by any author yet. In this work, a new and simple CMOS realization of VDTA is presented. The proposed block has two voltage inputs and two kinds of current output, so it is functional for voltage- and transconductance-mode operation. Furthermore, VDTA exhibits two different values of transconductance so that there is no need to external resistors for VDTA based applications which seems to be a good advantage for analog circuit designer. A CMOS implementation of VDTA and a voltage-mode VDTA based filter are proposed and simulated. An application example of fourth order flat-band band-pass amplifier is given and the performance of the circuit is demonstrated by comparing the theory and simulation

    Influence of distance from the host on parasitisation by Psyttalia concolor (Szépligeti) (Hymenoptera: Braconidae)

    Get PDF
    The olive fruit fly, Bactrocera oleae, is considered the main olive pest worldwide, and has been the target of biological control programmes through the release of the braconid parasitoid Psyttalia concolor. Laboratory tests were performed to evaluate the influence of distance from the host on parasitisation, placing larvae of the substitute host Ceratitis capitata at seven distances (0, 0.5, 1, 1.5, 2, 2.5, 3 mm) and four different time periods (7, 15, 30, 60 min). Moreover, field collected olives of Ogliarola Barese cultivar infested by B. oleae were exposed to P. concolor females to confirm its ability to parasitise B. oleae in small olives. Psyttalia concolor oviposition was inhibited at 2.5 and 3 mm due to the ovipositor length of the parasitoid females (2.7 mm). Hosts were easily parasitised at distances between 0 and 1.5 mm. The thin fruit pulp (up to 3.5 mm) of field collected olives allowed the parasitisation to occur also in mature fruits. At the best combination distance/time (0 mm, 30 min), tests performed with different larvae/parasitoid female ratio showed an increasing emergence of P. concolor (from 20% to 57%) with larvae/parasitoid ratio increasing from 0.11 to 0.74. The results of the present study might optimise the mass rearing of P. concolor, through a proper setting of its parameters, such as the host/parasitoid ratio, exposure distances, and interaction time

    A wideband linear tunable CDTA and its application in field programmable analogue array

    Get PDF
    This document is the Accepted Manuscript version of the following article: Hu, Z., Wang, C., Sun, J. et al. ‘A wideband linear tunable CDTA and its application in field programmable analogue array’, Analog Integrated Circuits and Signal Processing, Vol. 88 (3): 465-483, September 2016. Under embargo. Embargo end date: 6 June 2017. The final publication is available at Springer via https://link.springer.com/article/10.1007%2Fs10470-016-0772-7 © Springer Science+Business Media New York 2016In this paper, a NMOS-based wideband low power and linear tunable transconductance current differencing transconductance amplifier (CDTA) is presented. Based on the NMOS CDTA, a novel simple and easily reconfigurable configurable analogue block (CAB) is designed. Moreover, using the novel CAB, a simple and versatile butterfly-shaped FPAA structure is introduced. The FPAA consists of six identical CABs, and it could realize six order current-mode low pass filter, second order current-mode universal filter, current-mode quadrature oscillator, current-mode multi-phase oscillator and current-mode multiplier for analog signal processing. The Cadence IC Design Tools 5.1.41 post-layout simulation and measurement results are included to confirm the theory.Peer reviewedFinal Accepted Versio

    Predictors of diagnostic yield in bronchoscopy: a retrospective cohort study comparing different combinations of sampling techniques

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The reported diagnostic yield from bronchoscopies in patients with lung cancer varies greatly. The optimal combination of sampling techniques has not been finally established.</p> <p>The objectives of this study were to find the predictors of diagnostic yield in bronchoscopy and to evaluate different combinations of sampling techniques.</p> <p>Methods</p> <p>All bronchoscopies performed on suspicion of lung malignancy in 2003 and 2004 were reviewed, and 363 patients with proven malignant lung disease were included in the study. Sampling techniques performed were biopsy, transbronchial needle aspiration (TBNA), brushing, small volume lavage (SVL), and aspiration of fluid from the entire procedure. Logistic regression analyses were adjusted for sex, age, endobronchial visibility, localization (lobe), distance from carina, and tumor size.</p> <p>Results</p> <p>The adjusted odds ratios (OR) with 95% confidence intervals (CI) for a positive diagnostic yield through all procedures were 17.0 (8.5–34.0) for endobronchial lesions, and 2.6 (1.3–5.2) for constriction/compression, compared to non-visible lesions; 3.8 (1.3–10.7) for lesions > 4 cm, 6.7 (2.1–21.8) for lesions 3–4 cm, and 2.5 (0.8–7.9) for lesions 2–3 cm compared with lesions <= 2 cm. The combined diagnostic yield of biopsy and TBNA was 83.7% for endobronchial lesions and 54.2% for the combined group without visible lesions. This was superior to either technique alone, whereas additional brushing, SVL, and aspiration did not significantly increase the diagnostic yield.</p> <p>Conclusion</p> <p>In patients with malignant lung disease, visible lesions and larger tumor size were significant predictors of higher diagnostic yield, after adjustment for sex, age, distance from carina, side and lobe. The combined diagnostic yield of biopsy and TBNA was significant higher than with either technique alone.</p
    corecore